Micromold Products, Inc
(914)969-2850                                   Contact Us
 | 
 | 
 | 
 | 
 | 
Search Catalog
        
 Product Index    Double Flanged
Product Index > Reaction and Process Vessel Accessories > Dip Pipes & Spargers – PTFE Lined & Jacketed Steel > Double Flanged > View Items  

Double Flanged

Check up to five results to perform an action.


DDF Series Double Flanged Dip Pipes

Standard Double-Flanged Dip Pipes

Part Number: As shown here, the PART NUMBER (DDF-NS-MF-L1) defines the series (first three characters), the nominal tube and connecting flange size NS, the mounting (or nozzle) flange size MF, and the insertion length L1. Use a decimal number to indicate NS. Then, replace MF with the decimal number to indicate the nominal size of the mounting flange and replace L1 with the insertion length in inches.

For example, a 1-1/2” Double-Flange Dip Pipe with a 4” mounting flange x 60” insertion length would be DDF-1.5-4-60

Note 1: When used in a 1” nozzle, fits schedule 40 or thinner wall nozzles only.

Note 2: When used in a 1-1/2” nozzle, fits schedule 40 or thinner wall nozzles only.

Note 3: This size used with 2” nozzles only and fits schedule 40 or thinner wall nozzles only.

Note 4: This size used with 3-3/4” nozzles only and fits schedule 40 or thinner wall nozzles only.

Note 5: Click here to reference tables showing standard dimensions and mounting flange seal diameters.

Note 6: Standard flanges have ANSI Class 150 drilling. Class 300 and other sizes available.

Note 7: Standard tolerance on inserted length is ± 1/2”. Closer tolerances available, contact factory.

Note 8: Standard distance (L2) between flange sealing faces is 5”. Spacing is increased when a reinforcing collar is used. To order non-standard spacing, contact the factory.

Note 9: Most dimensions are governed by connecting flange size as shown in the Standard Dimension Table.

Note 10: Maximum standard overall length is 16 feet. For longer lengths, contact factory.

Note 11: For service conditions exceeding 350 F°, or 150 PSI, or vacuum service, contact factory.

Note 12:  Vent hole can be optionally fitted with a 1/4" half-coupling.






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 10 of 10 1 

Item #

Connecting Flange and
Nominal Tube Size
(inches)

PTFE Jacket OD
(OD1)
(inches)

PTFE Liner ID
(ID1)
(inches)

PTFE Seal OD
Minimum
(OD2)
(inches)

PTFE Seal OD
Minimum
(OD3)
(inches)

Steel Tube Thickness

1 1/2Note 1 1 7/16 1-1/4 See Note 5 0.109
2 3/4 1-1/4 5/8 1-9/16 See Note 5 0.113
3 1Note 2 1-1/2 3/4 1-7/8 See Note 5 0.179
4 1-1/2Note 3 2 1 2-11/16 See Note 5 0.140
5 1-1/2 2-1/4 1-1/8 2-11/16 See Note 5 0.200
6 2 2-3/4 1-5/8 3-7/16 See Note 5 0.218
7 3 3-3/4 2-1/2 4-5/8 See Note 5 0.250
8 3Note 4 3-15/16 2-1/2 4-5/8 See Note 5 0.300
9 4 5-1/8 3-1/2 5-15/16 See Note 5 0.337
10 6 6 4 8 See Note 5 0.250
  Results 1 - 10 of 10 1